Comfort
Comfort class
Based on the peak acceleration limit value the comfort class can be defined as:
Comfort class | Degree of comfort | |
---|---|---|
CL1 | Maximumm | |
CL2 | Medium | |
CL3 | Minimum | |
CL4 | Intolerable |
Based on the crest factor a further evaluation must be required if:
Crest factor () | Evaluation required |
---|---|
Basic | |
Detailed |
Recommended limit values for floor vibration serviceability based on the peak acceleration and the Maximum Transient Vibration Value (MTVV) according to:
-
BS 6472-1:2008: Guide to Evaluation of Human Exposure to Vibration in Buildings: Vibration Sources Other Than Blasting. British Standards Institution, 2008
-
A. L. Smith, S. J. Hicks, and P. J. Devine. Design of floors for vibration: A new approach. Steel Construction Institute Ascot, Berkshire, UK, 2007.
are given in the following table:
Floor type | MTVV | |
---|---|---|
Hospital | 0.005 | 0.007 |
Residential | 0.010 | 0.014 |
Office | 0.020 | 0.028 |
Workshops | 0.040 | 0.057 |